ni-9361. Member ‎04-24-2021 02:29 PM - edited ‎04-24-2021 02:53 PM. ni-9361

 
 Member ‎04-24-2021 02:29 PM - edited ‎04-24-2021 02:53 PMni-9361  Options

The values ke. 5. Originally I tried this with a cRIO-9045, NI-9361, NI-9234, NI-9213, and NI-9220, running RIO 19. Other parallel digital modules allow creating separate tasks for each one of. best regards Alexander 9361 two CTR. By using the Co-Browse feature, you are agreeing to allow a support representative from DigiKey to view your browser remotely. We have New & Used NI-9361 by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. vi ‏23 KB. * The NI 9361 is not actually able to access the chassis on-board counters, but it is the only module that has built-in counters itself; that is the reason it is included on this list ** The NI 9402 can operate at 20 MHz if two or fewer channels are used The workaround consists of performing the following steps on each channel individually (typically in a for loop): Create a task for the single channel. NI-VISA. We stock surplus new and reconditioned National Instruments cards with a 1 year warranty. com | NI 9361 Datasheet. 指定的采样率必须是源的一个除数。. ni-daqmx. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; I have 3 linear encoder and I will use NI9361. The NI‑9361 is a differential or single-ended input module. NI is now part of Emerson. Follow these guidelines if you are installing the NI 9361 in a potentially explosive environment. Reported In shows products that are verified to work for the solution described in this article. Generally an NI CompactDAQ Chassis has four built-in counters, so four encoders can be measured by a single CompactDAQ chassis. Pulse width: 100ms. When the value of this property is set to zero (default), the feature is disabled. Bl. But, my flow meter doesn’t have separate pin for Vin and GND. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. The other components in. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can check the LabVIEW-EtherCAT compatibility by viewing the Readme files in the EtherCAT driver. NI-DAQmx. In the script below, I used a comparison between the actual and. The NI‑9361 is a differential or single-ended input module. View all articles. ni-daqmx. 32-Bit, 8-Channel C Series Counter Input Module. niの集録および信号調整デバイスをサポートします。 ni-visa. ni gpib 컨트롤러 및 gpib 포트가 있는 ni 임베디드 컨트롤러에 대한 지원을 제공합니다. I'm working on a project where I need to run an encoder using LabVIEW and using a cDAQ 9185 with the NI 9361 module. To activate the onboard counter support, go to File - Preference - Preview features and activate Enablle the use of onboard counters for cDAQ chassis. The NI 9361 supports pulse measurements only for CompactRIO systems. NI-VISA. NI-9361; NI-9402 . 2 counter input edge count channels thus require 2 tasks. Provides support for NI GPIB controllers and. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。You can connect single-ended devices, such as TTL or CMOS to the NI 9361. The NI-9361 has 8 built-in counters in a module. NI-9361 is a counter input module and does not support pulse generation. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。 You can connect single-ended devices, such as TTL or CMOS to the NI 9361. NI-488. 이 문제는 마지막으로 설정한 터미널을 제외하고 태스크의 모든 채널에서 나타납니다. The NI‑9361 is a differential or single-ended input module. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. 0. I have tried to changed every parameters even the channel but not work. ni软件受版权法及其他知识产权法的保护。在将ni软件用于复制为他方所有的软件或其他资料的任何场合,ni软件仅可用于在符合许可证或其他法律限制的情况下复制上述资料。. It wil be connected single ended encoder. And went through the NI9361 Manual and realized the connections for open collector output to be as file attached as NI open collector. We are using the 9361 for two quadrature encoders (ie 2x 3 input channels) and the 9402 for IRIG time-sync, and need to program both in FPGA. 0 Replies 1 New. È possibile configurare ogni canale per la lettura di un singolo treno a impulsi oppure combinarli per la lettura fino a quattro encoder incrementali. Knight of NI. niの集録および信号調整デバイスをサポートします。 ni-visa. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. The 9361 DI+ and DI- input ranges are +0 to +5V, they have overvoltage protection up to +/-30V but we should keep the input signals within the operating range. While this expands the number of counters available to the system, the number of encoders you can connect to the module depends on the type of measurement you want to take. The NI 9361 Counter Input Module by National Instruments is In Stock & Ready to Ship at Apex Waves. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8-slot chassis. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。NI-DAQmx. If you need to use multiple counters from the NI 9361, you need to add all the required counters to the same task. Re: Frequency modulation for Veristand. ni-9361 揮発性に関する文書 修理のご依頼、キャリブレーションご予約、技術サポートをご利用いただけます。 ご利用にはサービス契約が必要となる場合があります。The PXIe‑6361 offers analog I/O, digital I/O, and four 32‑bit counter/timers for PWM, encoder, frequency, event counting, and more. ‡ The NI 9361 only supports a single task. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. For more information about. 0x749B. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. The issue i am having is that when I build an exe and deploy it, it works I get the data i want. 07-27-2021 04:31 PM. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. 2. Refer to the NI DAQmx Help for the valid channel names for the Counter module. Roman, unfortunately it is not possible to configure a pulse generation in NI VeriStand. NI-DAQmx. Since NI-9361 only supports a single task, you need to add all the counters to the same task. NI-9361. NI-9361은 단일 태스크 만 지원하므로 모든 카운터를 동일한 태스크에 추가해야합니다. Description. ni 9361 conformal coated, 8-ch counter input c series module rohs compliant: yes . The NI 9361 Counter Input module uses one AI Timing Engine, which limits the number of available AI tasks. CompactDAQ CompactDAQ-Chassis. I'm trying to read data from port ctr1 of NI 9361 as a counter channel: AngularEncoderChannel. The NI‑9361 is a differential or single-ended input module. 2. The methods of measuring the phase are based on analog signal characteristics when there are real and imaginary components in the signal, but the digital and counter signals do not contain an imaginary component, so it is not possible to measure the phase shift with the NI-9361 Counter Input module. Member ‎04-24-2021 02:29 PM - edited ‎04-24-2021 02:53 PM. 32-Bit, 8-Channel C Series Counter Input Module. To look at all of the counter modules and devices see the following page: Counters and Timers. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. I am fairly new to using LabView so would appreciate any help if possible - I have setup the encoder in LabView so that I can read the linear position of the encoder at any point in time. the NI 9361. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. The NI‑9361 is a differential or single-ended input module. Member. DI+. I would be happy for a recommendation on this subject. 32-Bit, 8-Channel C Series Counter Input Module. ni-9361 揮発性に関する文書 修理のご依頼、キャリブレーションご予約、技術サポートをご利用いただけます。 ご利用にはサービス契約が必要となる場合があります。The PXIe‑6361 offers analog I/O, digital I/O, and four 32‑bit counter/timers for PWM, encoder, frequency, event counting, and more. You can also directly connect sensors with. . Below link is the LabVIEW example page that demonstrates how to continuously acquire velocity measurements using the NI 9361. If the difference between the terminals is within the input. From there I want to determine if the frequency measured is within a certain range or not. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. 例如,X系列板卡上的默认时钟源是板载时钟(100MHz)。. The NI 9361 only supports a single task. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. Options. The first sample clock pulse must come after the first cycle of the input pulse signal has finished. We are using the 9361 for two quadrature encoders (ie 2x 3 input channels) and the 9402 for IRIG time-sync, and need to program both in FPGA. The issue is very similar to what has been described above. NI-VISA. Steps to Implement or Execute Code Change the Counter Physical Channels and Input Terminal as necessary. The other components in the system might not meet the same safety ratings. Generally an NI CompactDAQ Chassis has four built-in counters, so four encoders can be measured by a single CompactDAQ chassis. ni의 수집 및 신호 컨디셔닝 디바이스에 대한 지원을 제공합니다. It wil be connected single ended encoder. 4 kHz「ビジョン」では、niがテストとテクノロジの世界で次に何が起こるかをどのように認識しているかについて紹介します。. 이 문제는 마지막으로 설정한 터미널을 제외하고 태스크의 모든 채널에서 나타납니다. 02-26-2020 03:51 AM. Provides support for NI GPIB controllers and. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. Additional Information. 2. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. Pulse valuse: 1kg per Pulse. I have a NI 9361 module. The counter measures the high and low durations of a pulse on a signal. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 2. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. NI-VISA. ni-daqmx. This encoder is a single ended open collector device which requires the use of the internal pull ups available the NI module. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. You can refer to the example vi in LabVIEW. You can take pulse or duty cycle measurements with the NI 9361. . Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. NI 9361 Multiple Counter Channel Issue using DAQmx. USB DAQ DeviceThe NI‑9361 is a differential or single-ended input module. digital i/p module, compactdaq/rio sys, product type:digital input module, sampling rate:-, resoluti. The NI‑9361 is a differential or single-ended input module. . NI-9361 Dimensional Drawings. NI. But the read data abnormal occur periodic. Order by Part Number or Request a Quote. NI 9361: FlexLoggerは、 NI 9361 のプルアップ抵抗機能および入力電圧しきい値をサポートしています。 Cシリーズデジタルモジュール (シリアルデジタルI/O) NI 9375: NI 9375は、プロジェクトで一度に1個のポート (入力または出力) のみを使用できます。NI 9361 counter configuration pull-up resistor by ArieSafari on ‎07-11-2023 04:03 PM. You can also directly connect sensors with. The NI-9361 counter input module features 8 channels that you can configure as diferential or single ended for a CompactDAQ or CompactRIO system. Long cables and wires act as antennas, picking up extra noise that can affect measurements. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 00 783393-02. 05-14-2020 04:06 AM. As an alternative, you can use. I am using the NI 9361 a digital input counter and the cDAQ-9184. Page 1 GETTING STARTED GUIDE NI 9361 8 Counter DI, 0 V to 5 V Differential/0 V to 24 V Single-Ended, 32 Bit, 102. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Alternatively, look at cDAQ Module Support for Accessing On-board Counters . NI-488. For RSE input, however, FlexLogger does not support changing the input voltage. The NI‑9361 is a differential or single-ended input module. Yes, both the PWM Frequency and PWM Duty Cycle are measured in one single DAQmx Task using two separate virtual channels. My program is as attached below. So connected Vout to +24 and then +24 to DI0+. The NI 9361 has 8 embeded counters; If you need to use multiple counters from the NI 9361, you need to add all the required counters to the same task. 2. NI-9361. Only the NI 9361 C. For example, The guid. 5. $486. The counter measures the high and low durations of a pulse on a signal. However, while working with an NI 9361 module (on a cDAQ-9188 chassis), I notice the following error: DAQmx Error: The specified resource is reserved. NI-VISA. This guide will discuss through NI naming terminology, wiring considerations, signal mapping and pinouts, choosing the right. While working with NI counter input channels in the past, we have been advised to add channels to their own tasks. Select the channel from which you are acquiring the data and use the drop-down menu to configure the measurement mode to Pulse width. The NI‑9361 is a differential or single-ended input module. Click OK. . Complete the following steps to change the output drive setting: Select Create New Task. This feature makes the counter return a measurement value of 0Hz when the input signal period is larger than this value. Hi, My requirement is to measure angle using incremental rotary encoder. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. 2. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. Calibration Executive 5. com/calibration. NI-9361 / 783407-01 - NI. 0 Replies 521 Views 0 Kudos. Dear Labviewers, I am working on a project for the measurement of the voltage that it is triggered using a digital counter event. NI 9361; Note: FlexLogger does not support pull-up resistor functionality. NI-DAQmx. As in this VI, I want to use the Counter 1D Pulse Freq 1Chan NSamp type reading, so that I get a Cluster with frequency and duty cycle. This article explains and walks you through how to create simulated NI-DAQmxdevices in NI MAX. 유효한 서비스 계약이 필요할 수 있습니다. ‡ The NI 9361 only supports a single task. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。I have configured 4 different simulated NI modules (figure 1). 05-22-2019 08:11 AM. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. You can also directly connect sensors with open-collector or push-pull outputs by using an internal. CALIBRATION PROCEDURE NI 9361 8-Channel Counter Input Module This document contains the verification procedure for the NI 9361. I am using four of the inputs to change the count direction of each of the signals. KOMPLETE 14 STANDARD(标准版) 包含着适用于任何流派和风格的声音工具,它将 NI 最好的产品都囊括入内。你将在这里探索到我们的旗舰合成器、富有表现力的采样音源,以及专业工作室级别效果器,包含最新发布的 KONTAKT 7、PLAYBOX、40’S VERY OWN DRUMS & KEYS 以及 SESSION GUITARIST – ELECTRIC MINT,外加上来自iZotope. 2. NI-DAQmx. 2. Only the NI 9361 C Series Counter Input Modules and the NI 9326 Frequency Input Modules supports this method. rivlin. This document describes encoder theory, the basics of measuring an encoder, and options for measuring encoders use NI hardware. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. With this, you can provide a custom scale and unit to translate pulses to the volume measured by your sensor. ni 9265 隔离dac com vsup 保护 dc/dc ni 9265 产品规范 除非另外声明,否则下列规范的适用温度范围均为-40 °c~70 °c。所有电压均以com 端电压为参考地。 警告 如要确保指定的emc 性能,必须使用屏蔽式线缆和套件操作本产品。 警告 请勿尝试采用本文档中未提到的方式. NI-DAQmx. The NI 9361 supports pulse measurements only for CompactRIO systems. These considerations would apply to the hardware in FlexLogger, LabVIEW, etc. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。ni-daqmx. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. The waveforms changed. Provides support for NI data acquisition and signal conditioning devices. " In LabVIEW, you will need to configure the measurement method of the DAQmx Create Virtual Channel >> CI. NI-488. Hello, I am a mechanical engineering student working on a dynamometer project. niの集録および信号調整デバイスをサポートします。 ni-visa. Perspectives showcases how NI sees what’s next in the world of test and technology. I don't think I am seeing all the configuration options when I click on the 9361 device on MAX. Configuring NI 9361 Terminal Ismail. With either of the above modules, it will be possible to measure duty cycle with a single counter using a single physical and virtual channel. You can use the digital module to access the counters on the cDAQ chassis, and generate a pulsetrain using those counters. in the LabVIEW examples there is a Counter - Read Pulse Duty Cycle and Frequency (Continuous). 07-15-2010 08:24 AM. I have the basic idea figured out so far. 0 Kudos Message 5 of 5 (5,476 Views) Reply. - NI Silver Alliance Partner. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. I want to confirm that this is the correct module to use for this type of signal output. Refer to the documentation for each component in the system to determine the safety. Provides support for NI GPIB controllers and. According to my. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. DSA module such as NI 9234 uses its internal clock for sampling, so you need to use this sample clock or same timebase for CI frequency task in order to synchronize two tasks. In the official documentation is an example to run a task on a different thread asynchronously you can use this with a few changes. The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. 02-29-2016 11:43 AM. NI-DAQmx. • Maintain an ambient temperature of 23 °C ± 5 °C. Solution. Move on to the next channel, until each channel has gone through these steps. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. 시스템이나 소프트웨어를 업그레이드하거나 업데이트할 때, 이 정보를 참조하여 올바른 버전을 설치하십시오. At lower frequencies, 2k ticks quantization gives a comparatively low quantization error, and its hard to no. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. NI 9201E with DSUB. 由于NI-9361仅支持单个 DAQmx任务,因此您需要将所有计数器添加到同一任务中。. We have an example IRIG code for the 9402 in FPGA that compiles and executes without error The NI‑9361 is a differential or single-ended input module. . niの集録および信号調整デバイスをサポートします。 ni-visa. NI 9237の中の使用する アナログ入力 チャンネルを選択し、グローバル仮想チャンネルの名前を入力します. e. train or combine them to read. Page 4 Lower Limit Upper Limit 1,000,000 Hz 999,950 Hz 1,000,050 Hz If the Base Clock Accuracy verification procedure determines that the NI 9361 is outside of the limits, refer to Worldwide Support and Services for assistance in returning the device to NI. NI-DAQmx. 0 readme for details about that installation. C Series Digital Modules (serial digital I/O) NI 9375: The NI 9375 can only use one port (input or output) at a time in a project. niの集録および信号調整デバイスをサポートします。 ni-visa. Options. As an alternative, you can use Analog Voltage. 2. I do not really know who is best to use. 1は、ni 9361およびni 9469モジュールの問題を解決します。 NIは、すべてのユーザがドライバを可能な限り最新バージョンにアップデートすることを推奨しますが、NI 9361/NI 9469のユーザにはこのアップデートの適用を強く推奨します。niの集録および信号調整デバイスをサポートします。 ni-visa. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。Performs counter timer tasks such as encoder position measurement, event counting, period measurement, pulse measurement, and frequency measurement in C Series systems. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。 用计数器9361采集频率信号,被测信号60kHz。 但是采集过来的数据在正常和不正常之间稳定切换,能改的vi. We have New & Used NI-9361 by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. niの集録および信号調整デバイスをサポートします。 ni-visa. 5 up through 16. Namely. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. Relooking through the specifications, you'll need a logic level translator/inverter to convert your negative pulse to a positive one. The NI‑9402 is a per‑channel configurable digital I/O interface for input or output. I've been tasked with setting up a DAQ to be able to take in several square waves, from 0 to 5v, to count the number of actuations and cumulative on time of a few solenoids. • Keep connections to the NI 9361 as short as possible. Options. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. NI-9361 Frequency Measurement Returns Last Value Instead of 0Hz. For single-ended connections, connect the device out to the DI+ terminal on the NI 9361. 이 경우 카운터 수에 영향을 주는 가능한 모든 설정도 포함되었습니다. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. e. 在 配置面板中 ,展开 我的系统 树. I have the DAQ assistant set up (DAQ Assistant 2) to count the edges, but I need to add the pull up resistor as well. Solution Since NI-9361 only supports a single task, you need to add all the counters to the same task. While NI encourages all users to update drivers to the most recent versions whenever possible, this update is strongly recommended for NI 9361 and/ or NI 9469 users. I'm using NI's C# api. I am trying to perform some order analysis with the cDAQ hardware. niの集録および信号調整デバイスをサポートします。 ni-visa. Is there a mode to run the hardware in "old fashion" counter mode? I'd like to have one single entry in the. niの集録および信号調整デバイスをサポートします。 ni-visa. The NI-9361 returns the current count value when the counter is read. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. Re: Running Multi-Counters with NI9361. For a position measurement, you would need 3 digital lines per. >> 신호 수집 >> 카운터 입력 >> 주기 (측정 유형) >> cDAQ1Mod1 (모듈 번호) >> ctr0 (카운터 번호Solution. The 9361 module has 8 counters in its hardware. The engine runs at 2700RPM (max speed) and my encoder will end up producing 32. Actually, I have also NI-9221, NI-9203, NI-9361, NI-9223, and NI 9215. I was just trying to determine if there were internal pull-up options available other than the 9361 module. 2. The NI 9361 has 8 embeded counters; If you need to use multiple counters from the NI 9361, you need to add all the required counters to the same task. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。NI-DAQmx. For example, The guid. Unterstützte Hardware. 0のシステム要件は、次のとおりです。Find the National Instruments NI 9361 at our website: Click HERE. NI-DAQmx 문의사항 아래 문제 중 하나가 있습니다. CompactDAQ نام تجاری دستگاه‌های اندازه‌گیری شرکت NI بوده که. 36 and. You can also directly connect sensors with. Is the NI-9361 the only module with internal switchable pull-up resistors? 0 Kudos Message 1 of 4 (125 Views) Reply. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. Is this correct? Bob Young. However, FPGA Addon Custom Device allows you to do pulse measurement and generation using Speciality IO with C Series Digital I/O modules at a lower cost. 11-27-2017 10:04 AM. The waveforms changed periodically. 같은 태스크 안에서 이러한 프로퍼티를 설정할 수 없는 이유는 무엇이고. 2770-783407-01. 有关可. It is possible to do pulse measurement with NI-9361 using FPGA mode. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. The cRIO-9045 is a rugged, high-performance, customizable embedded controller that offers Intel Atom dual-core processing, NI-DAQmx support, and an SD card slot for data-logging, embedded monitoring, and control. 由于NI-9361仅支持单个 DAQmx任务,因此您需要将所有计数器添加到同一任务中。. -25 to DI0- and to ground. I have made the hardware wiring and tried to capture angle using NI MAX. 展开 NI 运动设备 树. Provides support for NI GPIB controllers and. NI-488. Commit the Terminal Configuration and/or Logic Level Behavior properties. With this, you can provide a custom scale and unit to translate pulses to the volume measured by your sensor. 5v would be the on position, 0v the off. Provides support for NI GPIB controllers and. 5 or later on the calibration system. We have an example IRIG code for the 9402 in FPGA that compiles and executes without errorThe NI‑9361 is a differential or single-ended input module. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. Order by Part Number or Request a Quote. Move on to the next channel, until each channel has gone through these steps. Additional Information The FlexLogger Plugin Development Kit is a software add-on that you can use to create LabVIEW plugins to communicate with third-party instrumentation. ethernet、gpib、シリアル、usbおよびその他のタイプの計測器をサポートします。 ni-488. I am assuming that all counter sources will become counter A's regardless of the card. 2. 您可以使用两个通道创建DAQmx任务,如下所示。. I was just trying to determine if there were internal pull-up options available other than the 9361 module. I can't change the properties for just one channel in a DAQmx Task. 1 -- Patch for NI 9361 and NI 9469 Users: Run-Time SoftwareThe NI 9361 only supports a single task. 2. When the Co-Browse window opens, give the session ID that is located in the toolbar to the representative. 0.